Power Supply

Fused Spur (fused connection unit)

In short

A fused spur is a switch and a fuse in one small box on the wall. Its proper name is a fused connection unit (FCU). Its terminals: L, N, E.

Fused Spur as drawn in the simulator

If this is your home: this page is written for heating engineers. Mains wiring and gas appliances are not DIY jobs; call a Gas Safe registered engineer. If you smell gas, leave the building and call the National Gas Emergency Service on 0800 111 999.

What it is

A FUSED SPUR is a switch and a fuse in one small box on the wall. Its proper name is a fused connection unit (FCU). The whole heating system is fed from it.

It is also the one place where the system is switched off, and locked off, before work.

Inside is a DOUBLE-POLE switch: it breaks the live (L) and the neutral (N) together. A FUSE sits on the live. For a gas boiler's controls it is 3 amps (3 A): the appliance's manual gives the size.

Terminals

TerminalWhat it is forOn the S-Plan exampleOn the Y-Plan exampleOn the Combi example
L (Live)The live (L) out. It runs through one side of the switch, then through the fuse.Wiring centre block 1Wiring centre block 1Combi Boiler L
N (Neutral)The neutral (N) out. It runs through the other side of the same switch.Wiring centre block 2Wiring centre block 2Combi Boiler N
E (Earth)The earth (E) out. It goes straight through: it is never switched and never fused.Wiring centre block 3Wiring centre block 3Combi Boiler E

Read from the wired example circuits: S-Plan, Y-Plan, Combi boiler with a wireless thermostat. A wiring-centre block carries whatever is landed on it; the numbers are the habit the lessons teach.

What the meter reads

Switched on, its live (L) and neutral (N) feed the wiring centre, and from there the rest of the system.

On site the earth is never switched. Its earth (E) stays joined to the supply's earth, with the spur on or off.

In this simulator the spur is the supply itself. Switched off, it gives no live, no neutral and no earth. The earth path is still there: with the power off, a continuity test proves it.

Switched off, the live and the neutral are dead at every part the spur feeds. That is why it is the POINT OF ISOLATION: the place you switch off before work.

Call-outs with this part on the path

Where it connects

Lessons that use it

Read the explanation

Practise it in the simulator.