In short

A wiring centre is the box where the wires of a heating system meet and are joined. Its terminals: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12. The parts list also has it as Compact Wiring Centre.

Wiring Centre as drawn in the simulator

If this is your home: this page is written for heating engineers. Mains wiring and gas appliances are not DIY jobs; call a Gas Safe registered engineer. If you smell gas, leave the building and call the National Gas Emergency Service on 0800 111 999.

What it is

A WIRING CENTRE is the box where the wires of a heating system meet and are joined.

This one has twelve numbered BLOCKS. Each block is a plain conductor: every wire landed on a block is joined to every other wire on that block. No block is joined to any other.

The numbers are a habit that helps, not a rule the box knows.

Terminals

TerminalWhat it is forOn the S-Plan exampleOn the Y-Plan exampleOn the Combi example
1Block 1.Fused Spur L, Heat-Only Boiler L, 2-Port Valve (heating) G, 2-Port Valve (hot water) G, Dual Channel Programmer LFused Spur L, Dual Channel Programmer L, Heat-Only Boiler LRoom Thermostat #1 L, DrawWarm Combi OUT_L, 2-Port Valve (heating) G, Room Thermostat #2 L, 2-Port Valve (second heating zone) G
2Block 2.Fused Spur N, Circulation Pump N, 2-Port Valve (heating) N, Heat-Only Boiler N, Room Thermostat N, 2-Port Valve (hot water) N, Dual Channel Programmer NFused Spur N, Circulation Pump N, Room Thermostat N, Dual Channel Programmer N, Heat-Only Boiler N, 3-Port Valve NDrawWarm Combi OUT_N, Room Thermostat #1 N, 2-Port Valve (heating) N, Room Thermostat #2 N, 2-Port Valve (second heating zone) N
3Block 3.Heat-Only Boiler E, 2-Port Valve (heating) E, 2-Port Valve (hot water) E, Dual Channel Programmer E, Fused Spur E, Circulation Pump EFused Spur E, Circulation Pump E, Dual Channel Programmer E, Heat-Only Boiler E, 3-Port Valve EDrawWarm Combi OUT_E, 2-Port Valve (heating) E, 2-Port Valve (second heating zone) E
4Block 4.Room Thermostat L, Dual Channel Programmer 4Dual Channel Programmer 4, Room Thermostat L—
5Block 5.Room Thermostat SL, 2-Port Valve (heating) BRoom Thermostat SL, 3-Port Valve WRoom Thermostat #1 SL, 2-Port Valve (heating) B
6Block 6.Cylinder Thermostat C, Dual Channel Programmer 3Dual Channel Programmer 3, Cylinder Thermostat C—
7Block 7.—Dual Channel Programmer 1, 3-Port Valve G, Cylinder Thermostat 2—
8Block 8.Cylinder Thermostat 1, 2-Port Valve (hot water) BCylinder Thermostat 1, Heat-Only Boiler SL, 3-Port Valve O—
9Block 9.——Room Thermostat #2 SL, 2-Port Valve (second heating zone) B
10Block 10.2-Port Valve (heating) O, 2-Port Valve (hot water) O, Heat-Only Boiler SL—DrawWarm Combi RT, 2-Port Valve (heating) O, 2-Port Valve (second heating zone) O
11Block 11.———
12Block 12.———

Read from the wired example circuits: S-Plan, Y-Plan, Combi boiler with two heating zones. A wiring-centre block carries whatever is landed on it; the numbers are the habit the lessons teach.

What the meter reads

The Draw Warm Method numbers the blocks:

  • 1: the live (L).
  • 2: the neutral (N).
  • 3: the earth (E).
  • 4: the central heating (CH) demand, to the room thermostat (stat).
  • 5: the call of the room thermostat.
  • 6: the hot water (HW) demand, to the cylinder thermostat.
  • 7: the Y-Plan's grey.
  • 8: the call of the cylinder thermostat. A Y-Plan's orange is on 8 too.
  • 10: the S-Plan's oranges, to the boiler's switched live (SL).

DrawWarm's lessons use block 9 for a second heating zone's call.

The numbering is a habit: read the schedule, never assume.

Call-outs with this part on the path

Where it connects

Lessons that use it

Read the explanation

Practise it in the simulator.